Skip to main content Skip to navigation
Range

TARIM Brume 47

Pattern : Stripe
Group B

Abstract pattern on striped background.

Fitting
L. : 35.0 cm - H. : 35.0 cm
The direction of use of the fabric may vary according to the chosen support. Normal direction if fabric is small width, counter direction if fabric is large width.

For the choice of the printing support and its width (width), please contact us.

Fabric to print
+ filters
Composition
100% polyester
Weight
260 g/m2
Width
140 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex
Fire ranking
NF 12952
Acoustic
Noise reduction coefficient (NRC) :0.88 Weighted sound absorption coefficient (αw) :0.90 Acoustic absorption class :A
Resilience
Martindale (Cycles)0
  • Dimentional Stability (%)
    • Warp0
    • Weft0
  • Breaking Elongation
    • Warp17
    • Weft27
  • Breaking load (daN)
    • Warp87
    • Weft110
Panel curtains
Panel curtains
Lining
Lining
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% polyester
Weight
260 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex
Fire ranking
NF 12952
Acoustic
Noise reduction coefficient (NRC) :0.88 Weighted sound absorption coefficient (αw) :0.90 Acoustic absorption class :A
Resilience
Martindale (Cycles)0
  • Dimentional Stability (%)
    • Warp0
    • Weft0
  • Breaking Elongation
    • Warp17
    • Weft27
  • Breaking load (daN)
    • Warp87
    • Weft110
Panel curtains
Panel curtains
Lining
Lining
Curtains
Curtains
Roman blinds
Roman blinds
  • Flame retardant
  • Antiviral
  • Antibacterial
  • Acoustic
  • Thermal
    Thermal
Composition
100% bioactive polyester
Weight
140 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 60° maximum
  • Bleach using oxygenated agents only
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / B1 / IMO PASS / UNI 8456 / 9174 Classe Uno
Acoustic
Noise reduction coefficient (NRC) :0.72 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Antibacterial
Yes
Resilience
Lightfastness (units Class/8)5
Pilling5
Martindale (Cycles)14000
  • Dimentional Stability (%)
    • Warp-0.5
    • Weft-0.5
  • Breaking Elongation
    • Warp43
    • Weft37
  • Breaking load (daN)
    • Warp42
    • Weft129
Panel curtains
Panel curtains
Curtains
Curtains
Partition curtain
Partition curtain
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
260 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 30°C maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex
Fire ranking
M1 / IMO PASS
Optical index
Light reflexion51 %
Light absorption49 %
Light transmission0 %
Thermal index
Solar reflexion50 %
Solar absorption50 %
Solar transmission0 %
UV transmission0 %
GtotGt 41 % Fc 69 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)6
  • Dimentional Stability (%)
    • Warp-1
    • Weft-2
  • Breaking Elongation
    • Warp28
    • Weft24
  • Breaking load (daN)
    • Warp120
    • Weft78
Lining
Lining
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
260 g/m2
Width
145 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex
Fire ranking
M1 / B1 / IMO PASS / UNI 8456 / 9174 Classe Uno
Acoustic
Noise reduction coefficient (NRC) :0.88 Weighted sound absorption coefficient (αw) :0.90 Acoustic absorption class :A
Resilience
  • Dimentional Stability (%)
    • Warp0
    • Weft0
  • Breaking Elongation
    • Warp17
    • Weft27
  • Breaking load (daN)
    • Warp87
    • Weft110
Valences
Valences
Lining
Lining
Bed runners
Bed runners
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
260 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex
Fire ranking
M1 / B1 / IMO PASS / UNI 8456 / 9174 Classe Uno
Acoustic
Noise reduction coefficient (NRC) :0.88 Weighted sound absorption coefficient (αw) :0.90 Acoustic absorption class :A
Resilience
  • Dimentional Stability (%)
    • Warp0
    • Weft0
  • Breaking Elongation
    • Warp17
    • Weft27
  • Breaking load (daN)
    • Warp87
    • Weft110
Valences
Valences
Lining
Lining
Bed runners
Bed runners
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
230 g/m2
Width
140 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / IMO PASS
Acoustic
Noise reduction coefficient (NRC) :0.00 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion0 %
Light absorption0 %
Light transmission0 %
Thermal index
Solar reflexion0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)6
Pilling4
Martindale (Cycles)0
  • Dimentional Stability (%)
    • Warp1
    • Weft1
  • Breaking Elongation
  • Breaking load (daN)
    • Warp0
    • Weft0
Panel curtains
Panel curtains
Bedspreads
Bedspreads
Valences
Valences
Bed runners
Bed runners
Curtains
Curtains
Cushions
Cushions
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
230 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / IMO PASS
Acoustic
Noise reduction coefficient (NRC) :0.00 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion0 %
Light absorption0 %
Light transmission0 %
Thermal index
Solar reflexion0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)6
Pilling4
Martindale (Cycles)0
  • Dimentional Stability (%)
    • Warp1
    • Weft1
  • Breaking Elongation
  • Breaking load (daN)
    • Warp0
    • Weft0
Panel curtains
Panel curtains
Bedspreads
Bedspreads
Valences
Valences
Bed runners
Bed runners
Curtains
Curtains
Cushions
Cushions
Roman blinds
Roman blinds
Composition
100% polyester
Weight
230 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
NF 12952
Acoustic
Noise reduction coefficient (NRC) :0.00 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion0 %
Light absorption0 %
Light transmission0 %
Thermal index
Solar reflexion0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)6
Pilling4
Martindale (Cycles)0
  • Dimentional Stability (%)
    • Warp1
    • Weft1
  • Breaking Elongation
  • Breaking load (daN)
    • Warp0
    • Weft0
Panel curtains
Panel curtains
Bedspreads
Bedspreads
Valences
Valences
Bed runners
Bed runners
Curtains
Curtains
Cushions
Cushions
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
95 g/m2
Width
290 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / B1 / IMO PASS / UNI 8456 / 9174 Classe Uno
Optical index
Light reflexion3 %
Light absorption76 %
Light transmission21 %
Transparent veil
Yes
Thermal index
Solar reflexion23 %
Solar absorption37 %
Solar transmission40 %
UV transmission24 %
GtotGt 57 % Fc 81 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)4
  • Dimentional Stability (%)
    • Warp0
    • Weft0
  • Breaking Elongation
    • Warp46
    • Weft13
  • Breaking load (daN)
    • Warp41
    • Weft40
Panel curtains
Panel curtains
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
230 g/m2
Width
140 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 60° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / IMO PASS
Acoustic
Noise reduction coefficient (NRC) :0.90 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion5 %
Light absorption94 %
Light transmission1 %
Thermal index
Solar reflexion39 %
Solar absorption48 %
Solar transmission13 %
UV transmission0 %
GtotGt 48 % Fc 69 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)5
Pilling5
Martindale (Cycles)40000
  • Dimentional Stability (%)
    • Warp-2
    • Weft-1
  • Breaking Elongation
    • Warp38
    • Weft21
  • Breaking load (daN)
    • Warp150
    • Weft93
Panel curtains
Panel curtains
Bedspreads
Bedspreads
Valences
Valences
Bed runners
Bed runners
Curtains
Curtains
Cushions
Cushions
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
230 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 60° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / IMO PASS
Acoustic
Noise reduction coefficient (NRC) :0.90 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion5 %
Light absorption94 %
Light transmission1 %
Thermal index
Solar reflexion39 %
Solar absorption48 %
Solar transmission13 %
UV transmission0 %
GtotGt 48 % Fc 69 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)5
Pilling5
Martindale (Cycles)40000
  • Dimentional Stability (%)
    • Warp-2
    • Weft-1
  • Breaking Elongation
    • Warp38
    • Weft21
  • Breaking load (daN)
    • Warp150
    • Weft93
Panel curtains
Panel curtains
Bedspreads
Bedspreads
Valences
Valences
Bed runners
Bed runners
Curtains
Curtains
Cushions
Cushions
Roman blinds
Roman blinds
Composition
100% polyester with white flocked acrylic backing
Weight
310 g/m2
Width
140 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 30°C maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Fire ranking
M1 / IMO PASS
Acoustic
Noise reduction coefficient (NRC) :0.38 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion73 %
Light absorption27 %
Light transmission0 %
Thermal index
Solar reflexion64 %
Solar absorption36 %
Solar transmission0 %
UV transmission0 %
GtotGt 37 % Fc 52 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)5
  • Dimentional Stability (%)
    • Warp0
    • Weft0
  • Breaking Elongation
    • Warp38
    • Weft27
  • Breaking load (daN)
    • Warp42
    • Weft64
Roller blinds
Roller blinds
Panel curtains
Panel curtains
Lining
Lining
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% polyester with white flocked acrylic backing
Weight
310 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 30°C maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Fire ranking
M1 / IMO PASS
Optical index
Light reflexion73 %
Light absorption27 %
Light transmission0 %
Thermal index
Solar reflexion64 %
Solar absorption36 %
Solar transmission0 %
UV transmission0 %
GtotGt 37 % Fc 52 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)5
  • Dimentional Stability (%)
    • Warp0
    • Weft0
  • Breaking Elongation
    • Warp38
    • Weft27
  • Breaking load (daN)
    • Warp42
    • Weft64
Roller blinds
Roller blinds
Panel curtains
Panel curtains
Lining
Lining
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% polyester with white flocked acrylic backing
Weight
280 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 30°C maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Fire ranking
Not Classified
Optical index
Light reflexion82 %
Light absorption18 %
Light transmission0 %
Thermal index
Solar reflexion74 %
Solar absorption26 %
Solar transmission0 %
UV transmission0 %
GtotGt 33 % Fc 55 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)5
  • Dimentional Stability (%)
    • Warp-0,5
    • Weft0
  • Breaking Elongation
    • Warp26
    • Weft15
  • Breaking load (daN)
    • Warp62
    • Weft31
Panel curtains
Panel curtains
Lining
Lining
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% polyester
Weight
80 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
France Terre Textile
Fire ranking
NF 12952
Acoustic
Noise reduction coefficient (NRC) :0.00 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion0 %
Light absorption0 %
Light transmission0 %
Thermal index
Solar reflexion0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)0
Martindale (Cycles)0
  • Breaking Elongation
  • Breaking load (daN)
    • Warp0
    • Weft0
Bedspreads
Bedspreads
Lining
Lining
Bed runners
Bed runners
Composition
100% polyester
Weight
80 g/m2
Width
180 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
France Terre Textile
Fire ranking
NF 12952
Acoustic
Noise reduction coefficient (NRC) :0.00 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion0 %
Light absorption0 %
Light transmission0 %
Thermal index
Solar reflexion0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)0
Martindale (Cycles)0
  • Breaking Elongation
  • Breaking load (daN)
    • Warp0
    • Weft0
Bedspreads
Bedspreads
Lining
Lining
Bed runners
Bed runners
Composition
100% FR polyester
Weight
220 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 60° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / IMO PASS
Acoustic
Noise reduction coefficient (NRC) :0.00 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion0 %
Light absorption0 %
Light transmission0 %
Thermal index
Solar reflexion0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)4
Martindale (Cycles)0
  • Dimentional Stability (%)
    • Warp-1
    • Weft-1
  • Breaking Elongation
    • Warp42
    • Weft22
  • Breaking load (daN)
    • Warp160
    • Weft140
Panel curtains
Panel curtains
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
220 g/m2
Width
140 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 60° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / IMO PASS
Acoustic
Noise reduction coefficient (NRC) :0.00 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion0 %
Light absorption0 %
Light transmission0 %
Thermal index
Solar reflexion0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)4
Martindale (Cycles)0
  • Dimentional Stability (%)
    • Warp-1
    • Weft-1
  • Breaking Elongation
    • Warp42
    • Weft22
  • Breaking load (daN)
    • Warp160
    • Weft140
Panel curtains
Panel curtains
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% FR polyester
Weight
50 g/m2
Width
290 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 40° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / B1 / IMO PASS
Optical index
Light reflexion5 %
Light absorption4 %
Light transmission71 %
Transparent veil
Yes
Thermal index
Solar reflexion25 %
Solar absorption3 %
Solar transmission72 %
UV transmission65 %
GtotGt 50 % Fc 85 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)6
  • Dimentional Stability (%)
    • Warp-1
    • Weft0
  • Breaking Elongation
    • Warp28
    • Weft34
  • Breaking load (daN)
    • Warp30
    • Weft36
Panel curtains
Panel curtains
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% polyester with white flocked acrylic coating
Weight
330 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 30°C maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
France Terre Textile
Fire ranking
M1 / EN13773 : 2003 Class 1 / B1 / IMO PASS / UNI 8456 / 9174 Classe Uno
Optical index
Light reflexion72 %
Light absorption28 %
Light transmission0 %
Thermal index
Solar reflexion70 %
Solar absorption30 %
Solar transmission0 %
UV transmission0 %
GtotGt 34 % Fc 57 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)5
Pilling4-5
Martindale (Cycles)20000
  • Dimentional Stability (%)
    • Warp-2
    • Weft-1,5
Roller blinds
Roller blinds
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% bioactive polyester
Weight
170 g/m2
Width
280 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 60° maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Label
OekoTex / France Terre Textile
Fire ranking
M1 / B1
Antibacterial
Yes
Panel curtains
Panel curtains
Curtains
Curtains
Partition curtain
Partition curtain
Roman blinds
Roman blinds
Composition
100% polyester with white flocked acrylic backing
Weight
340 g/m2
Width
140 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 30°C maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Fire ranking
M1 / IMO PASS
Acoustic
Noise reduction coefficient (NRC) :0.28 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Optical index
Light reflexion75 %
Light absorption25 %
Light transmission0 %
Thermal index
Solar reflexion67 %
Solar absorption33 %
Solar transmission0 %
UV transmission0 %
GtotGt 35 % Fc 60 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)6
  • Dimentional Stability (%)
    • Warp-0,5
    • Weft0
  • Breaking Elongation
    • Warp20
    • Weft24
  • Breaking load (daN)
    • Warp53
    • Weft63
Roller blinds
Roller blinds
Panel curtains
Panel curtains
Lining
Lining
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% ungraded polyester with white flocked acrylic backing
Weight
390 g/m2
Width
260 cm
Fabric direction
Standard Direction
?

Standard Direction

SD

Standard direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 30°C maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry clean only
Fire ranking
Not Classified
Optical index
Light reflexion73 %
Light absorption27 %
Light transmission0 %
Thermal index
Solar reflexion64 %
Solar absorption36 %
Solar transmission0 %
UV transmission0 %
GtotGt 37 % Fc 52 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)5
  • Dimentional Stability (%)
    • Warp-1
    • Weft0
  • Breaking Elongation
    • Warp52
    • Weft41
  • Breaking load (daN)
    • Warp69
    • Weft106
Panel curtains
Panel curtains
Curtains
Curtains
Roman blinds
Roman blinds
Composition
100% polyester with white flocked acrylic backing
Weight
390 g/m2
Width
273 cm
Fabric direction
Room High Direction
?

Room High Direction

RD

Room High Direction conception

Fitting
35.0-35.0
Maintenance advice
  • Wash at 30°C maximum
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Fire ranking
Not Classified
Resilience
  • Dimentional Stability (%)
    • Warp0
    • Weft0
  • Breaking Elongation
    • Warp38
    • Weft38
  • Breaking load (daN)
    • Warp170
    • Weft120
Panel curtains
Panel curtains
Curtains
Curtains
Roman blinds
Roman blinds